ENEC 301 Annex B

Ref. Standards Reference to PD ENEC 303 Product description Limitations Required Surveil-lance (Appendix A) Location Testing Laboratory **)
    Annexes       World-wide
E1 EN60598-1 Annex A Luminaires See note to item 1. Notfor standalone ENEC certification 1 X
E1.1 EN60598-2-1 Annex A Fixed generalpurpose luminaires no 1 X
E1.2 EN60598-2-2 Annex A Recessedluminaires no 1 X
E1.3 EN60598-2-3 Annex A Luminaires for road and street lighting no 1 X
E1.4 EN60598-2-4 Annex A Portable general purpose luminaires no 1 X
E1.5 EN60598-2-5 Annex A Floodlights no 1 X
E1.6 EN60598-2-6 Annex A Luminaires with built-in transformer for filament lamps no 1 X
E1.7 EN60598-2-7 Annex A Portable luminaires for garden use See note to item 1.7 1 X
E1.8 EN60598-2-8 Annex A Hand lamps no 1 X
E1.9 EN60598-2-9 Annex A Photo and film luminaires
(non-professional)
no 1 X
E1.10 EN60598-2-10 Annex A Portable child appealing luminaires no 1 X
E1.11 EN60598-2-11 Annex A Aquarium luminaires no 1 X
E1.12 EN60598-2-12 Annex A Mainssocket-outlet mounted night lights no 1 X
E1.13 EN60598-2-13 Annex A Groundrecessed luminaires no 1 X
E1.14 EN 60598-2-14 Annex A Luminaires for cold cathode tubular discharge lamps (neon tubes) and similar equipment no 1 X
E1.17 EN60598-2-17 Annex A Luminaires for stage lighting television and film studios (outdoor and indoor) no 1 X
E1.18 EN60598-2-18 Annex A Luminaires for swimming pools and similar application no 1 X
E1.19 EN60598-2-19 Annex A Air-handling luminaires (safety requirements) no 1 X
E1.20 EN60598-2-20 Annex B Lighting chains no 1 X
E1.22 EN60598-2-22 Annex A Luminaires for emergency lighting See note to item 1.22 1 X
E1.23 EN60598-2-23 Annex A Extralow-voltage lighting systems for filament lamps no 1 X
E1.24 EN60598-2-24 Annex A Luminaires with limited surface temperatures no 1 X
E1.25 EN60598-2-25 Annex A Luminaires for use in clinical areas of hospitals and health care buildings no 1 X
E2 EN 62031 EN62471 (incl. IEC 62471-2) Annex AJ LED modules for general lighting - Safety specifications Photo biological safety of lamps and lamp systems no 1 X
E7 EN 60155 Annex J Startersfor tubular fluorescent lamps no 1 X
E8 EN 61048 EN 61049 Annex N Capacitorsfor use in tubular fluorescent and other discharge lamp circuits -   Safety requirements -   Performance requirements no 1 X
E9 EN 60238 Annex L Edison lampholders no 1 X
E10 EN 60400 Annex L Fluorescentlamp holders no 1 X
E11 EN60838-1 Annex L Miscellaneous lamp holders no 1 X
E11.1 EN60838-2-1 Annex L Lampholders S14 no 1 X
E11.2 EN60838-2-2 Annex L Connectors for LED modules no 1 X
E13 EN 61184 Annex L Bayonet lamp holders no 1 X
E15 EN 60570 Annex S Electrical supply track systems for luminaires See note to item 15 1 X
E16.1 EN60950-1 Annex O Information technology equipment – Safety
Part 1: General requirements
no 2 X
E17 EN 60968     Annex R Self-ballasted lamps for general lighting services - Safety requirements no 1 X
E17 EN60969 Annex R Self-ballasted lamps for general lighting services - Performance requirements no 1 X
E18 EN 61050 Annex Q Transformers for tubular discharge lamps having a no-load output voltage exceeding 100 V (neon transformers) no 1 X
E19 EN61558-1 Annex P Safety of power transformers, power supply units and similar no 2 X
E19.1 EN61558-2-1 Annex P Particular requirements for separating transformers for general use no 2 X
E19.2 EN61558-2-2 Annex P Particular requirements for control transformers no 2 X
E19.4 EN61558-2-4 Annex P Particular requirements for isolating transformers for general use no 2 X
E19.5 EN61558-2-5 Annex P Particular requirements for shaver transformers and shaver supply units no 2 X
E19.6 EN61558-2-6 Annex P Particular requirements for safety isolating transformers for general use no 2 X
E19.7 EN61558-2-7 Annex P Particular requirements for transformers for toys no 2 X
E19.8 EN61558-2-8 Annex P Bell and Chime transformers no 2 X
E19.16 EN61558-2-16 Annex P Particular requirements and test for switch mode power sup-ply units and transformers for switch mode power supply units no 2 X
E20 EN61058-1 Annex T Switchesfor appliances no 2 X

E20
EN61058-1-1 Annex T Switches for appliances - Part 1-1: Requirements for mechanical switches no 2 X

E20
EN61058-1-2 Annex T Switches for appliances - Part 1-2: Requirements for electronic switches no 2 X
E20.1 EN61058-2-1 Annex T Particular requirements for cord switches no 2 X
E20.2 EN61058-2-5 Annex T Particular requirements for change-over selectors no 2 X
E21 EN60730-1 Annex AB Automatic electrical controls for household and similar use Not for standalone ENEC certification 2 X
E21.2 EN60730-2-2 Annex AB Particular requirements for thermal motor protectors no 2 X
E21.3 EN60730-2-3 Annex AB Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps no 2 X
E21.4 EN60730-2-4 Annex AB Particular requirements for thermal motor protectors for motor-compressors of hermeticand semi-hermetic type no 2 X
E21.5 EN60730-2-5 Annex AB Particular requirements for automatic electrical burner control systems no 2 X
E21.6 EN60730-2-6 Annex AB Particular requirements for automatic electrical pressure sensing controls, including mechanical requirements no 2 X
E21.7 EN60730-2-7 Annex AB Particular requirements for timers and time switches no 2 X
E21.8 EN60730-2-8 Annex AB Particular requirements for electrically operated water valves, including mechanical requirements no 2 X
E21.9 EN60730-2-9 Annex AB Particular requirements for temperature sensing controls no 2 X
E21.10 EN60730-2-10 Annex AB Particular requirements for motor starting relays no 2 X
E21.11 EN60730-2-11 Annex AB Particular requirements for energy regulators no 2 X
E21.12 EN60730-2-12 Annex AB Particular requirements for electrically operated door locks no 2 X
E21.13 EN60730-2-13 Annex AB Particular requirements for humidity sensing controls no 2 X
E21.14 EN60730-2-14 Annex AB Particular requirements for electric actuators no 2 X
E21.15 EN60730-2-15 Annex AB Particular requirements for automatic electrical water level sensing controls of thefloat or electrode-sensor type used in boiler applications no 2 X
E21.16 EN60730-2-16 Annex AB Particular requirements for automatic electrical water level operating controls of thefloat type for household and similar applications no 2 X
E21.18 EN60730-2-18 Annex AB Particular requirements for automatic electrical water and air flow sensing controls,including mechanical requirements no 2 X
E24 EN60998-1 Annex V Connecting devices for low voltage circuits for household and similar purposes. Part 1:General requirements See note to item 24 1 X
E24.1 EN60998-2-1 Annex V Particular requirements for connecting devices as separate entities with screw-typeclamping units See note to item 24 1 X
E24.2 EN60998-2-2 Annex V Particular requirements for connecting devices as separate entities with screw-less-type clamping units See note to item 24 1 X
E24.3 EN60998-2-3 Annex V Particular requirements for connecting devices as separate entities with insulation piercing clamping units See note to item 24 1 X
E25 EN60999-1 Annex V Connecting devices – Electrical copper conductors See note to item 25 1 X
E26 EN60938-2 Annex U Fixed inductors for electromagnetic interference suppression Part 2:Sectional specification no 1 X

E27
EN61347-1 Annex E Lamp controlgear Part 1:General and safety requirements Not for standalone ENEC certification 1 X
E27.1 EN61347-2-1
EN 60927
Annex I Lamp controlgear –
Particular requirements for starting devices (other than glow starters) Starting devices (other than glow starters) - Performance requirements
no 1 X
E27.2 EN61347-2-2
EN 61047
Annex H Lamp controlgear –
Particular requirements for DC or AC supplied electronic step-down convertors for filament lamps DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements
no 1 X
E27.3 EN61347-2-3
EN 60929
Annex F Lamp controlgear –
Particular requirements for AC supplied electronic ballasts for fluorescent lamps AC-supplied electronic ballasts for tubular fluorescent lamps - Performance requirements
no 1 X
E27.4 EN61347-2-4
EN 60925
Annex E Lamp controlgear –
Particular requirements for DC supplied electronic ballasts for general lighting DCsupplied electronic ballasts for tubular fluorescent lamps - Performance requirements
no 1 X
E27.5 EN61347-2-5
EN 60925
Annex E Lamp controlgear –
Particular requirements for DC supplied electronic ballasts for public transport lighting DCsupplied electronic ballasts for tubular fluorescent lamps - Performance requirements
no 1 X
E27.6 EN61347-2-6
EN 60925
Annex E Lamp controlgear –
Particular requirements for DC supplied electronic ballasts for aircraft lighting DCsupplied electronic ballasts for tubular fluorescent lamps - Performance requirements
no 1 X
E27.7 EN61347-2-7 Annex E Lamp controlgear–
Particular requirements for DC supplied electronic ballasts for emergency lighting Thisstandard also includes operational requirements for ballasts which areregarded as performance
requirements (Clause 1 of 61347-2-7:2006)
no 1 X
E27.8 EN61347-2-8
EN 60921
Annex D Lamp controlgear –
Particular requirements for ballasts for fluorescent lamps Ballastsfor tubular fluorescent lamps - Performance requirements
no 1 X
E27.9 EN61347-2-9
EN 60923
Annex G Lamp controlgear –
Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) Ballastsfor discharge lamps (excluding tubular
fluorescent lamps) - Performance requirements
no 1 X
E27.10 EN61347-2-10 Annex AC Lamp controlgear –
Particular requirements for electronic invertors and convertors forhigh-frequency operation of cold start tubular discharge lamps (neon tubes)
no 1 X
E27.11 EN61347-2-11 Annex AC Lamp controlgear –
Particular requirements for miscellaneous electronic circuits used with luminaires
no 1 X
E27.12 EN61347-2-12 Annex AC Lamp controlgear –
Particular requirements for DC or AC supplied electronic ballasts for discharge lamps (excluding fluorescent lamps)
no 1 X
E27.13 EN61347-2-13
EN 62384
Annex AC Lamp controlgear –
Particular requirements for DC or AC supplied electronic controlgear for LED modules – Safety requirements DC or AC supplied electronic controlgear for LED modules - Performance requirements
no 1 X
E28 EN60320-1 Annex W Appliance couplers for household and similar purposes no 2 X
E28.1 EN60320-2-1 Annex W Sewingmachine couplers no 2 X
E28.2 EN60320-2-2 Annex W Interconnection couplers for household and similar equipment no 2 X
E28.3 EN60320-2-3 Annex W Appliance couplers with a degree of protection higher than IPX0 no 2 X
E28.4 EN60320-2-4 Annex W Couplers dependent on appliance weight for
engagement
no 2 X
E29 EN50075 Annex X Flatnon-rewirable two-pole plugs, 2,5 A 250 V, with cord See note to item 29 2 X
E30.1
EN60309-1 Annex Y Plugs,socket-outlets and couplers for industrial purposes -
Part 1: General requirements
Not for standalone ENEC certification 2 X
E30.2 EN60309-2 Annex Y Plugs,socket-outlets and couplers for industrial purposes -
Part 2: Dimensional interchangeability requirements for pin and contact-tubeaccessories
no 2 X
E30.4 EN60309-4 Annex Y Plugs,socket-outlets and couplers for industrial purposes - Part 4: Switched socket-outlets and connectors with or without interlock no 2 X
E31 EN60384-14 Annex U Fixed capacitors for electromagnetic interference suppression and connection to the supply mains no 2 X
E32 EN60939-2 Annex U Passive filter units for which safety tests are appropriate -
Test methods and general requirements
no 2 X
E32.2 EN60939-3 Annex U Passive filter units for electromagnetic interference suppression - Part 3: Passive filter units for which safety tests areappropriate no 2 X
E33 EN60335-1 Annex AD Household and similar electrical appliances -
General requirements
See note to item 33.
Not for standalone ENEC certification
2 X
E33.2 EN60335-2-2 Annex AD Vacuum cleaners and water suction See note to item 33 2 X
E33.3 EN60335-2-3 Annex AD Electric irons See note to item 33 2 X
E33.4 EN60335-2-4 Annex AD Spin extractors See note to item 33 2 X
E33.5 EN60335-2-5 Annex AD Dishwashers See note to item 33 2 X
E33.6 EN60335-2-6 Annex AD Stationary cooking ranges, hobs, ovens See note to item 33 2 X
E33.7 EN60335-2-7 Annex AD Washing machines See note to item 33 2 X
E33.8 EN60335-2-8 Annex AD Shavers, hair clippers See note to item 33 2 X
E33.9 EN60335-2-9 Annex AD Toasters, grills, roasters See note to item 33 2 X
E33.10 EN60335-2-10 Annex AD Floor treatment and wet scrubbing machines See note to item 33 2 X
E33.11 EN60335-2-11 Annex AD Tumbler dryers See note to item 33 2 X
E33.12 EN60335-2-12 Annex AD Warming plates See note to item 33 2 X
E33.13 EN60335-2-13 Annex AD Deep fat fryers, frying pans See note to item 33 2 X
E33.14 EN60335-2-14 Annex AD Kitchen machines See note to item 33 2 X
E33.15 EN60335-2-15 Annex AD Appliances for heating liquids See note to item 33 2 X
E33.16 EN60335-2-16 Annex AD Food waste disposers See note to item 33 2 X
E33.17 EN60335-2-17 Annex AD Blankets, pads See note to item 33 2 X
E33.21 EN60335-2-21 Annex AD Water heaters See note to item 33 2 X
E33.23 EN60335-2-23 Annex AD Appliances for skin and hair care See note to item 33 2 X
E33.24 EN60335-2-24 Annex AD Refrigerators, food freezers and icemakers See note to item 33 2 X
E33.25 EN60335-2-25 Annex AD Microwave ovens See note to item 33 2 X
E33.26 EN60335-2-26 Annex AD Clocks See note to item 33 2 X
E33.27 EN60335-2-27 Annex AD UV and IR skin treatment appliances See note to item 33 2 X
E33.28 EN60335-2-28 Annex AD Sewing machines See note to item 33 2 X
E33.29 EN60335-2-29 Annex AD Battery chargers See note to item 33 2 X
E33.30 EN60335-2-30 Annex AD Room heaters See note to item 33 2 X
E33.31 EN60335-2-31 Annex AD Range hoods See note to item 33 2 X
E33.32 EN60335-2-32 Annex AD Massage appliances see note to item 33 2 X
E33.34 EN 60335-2-34 Annex AD Motor compressors See note to item 33 2 X
E33.35 EN60335-2-35 Annex AD Instantaneous water heaters See note to item 33 2 X
E33.36 EN60335-2-36 Annex AD Commercial electric cooking ranges See note to item 33 2 X
E33.37 EN60335-2-37 Annex AD Commercial electric deep fat fryers See note to item 33 2 X
E33.38 EN60335-2-38 Annex AD Commercial electric griddles See note to item 33 2 X
E33.39 EN60335-2-39 Annex AD Commercial electric multi-purpose cooking pans see note to item 33 2 X
E33.40 EN60335-2-40 Annex AD Heat pumps, air conditioners & dehumidifiers See note to item 33 2 X
E33.41 EN60335-2-41 Annex AD Pumps for liquids See note to item 33 2 X
E33.42 EN60335-2-42 Annex AD Commercial electric forced convection ovens See note to item 33 2 X
E33.43 EN60335-2-43 Annex AD Clothes dryers and towel rails See note to item 33 2 X
E33.44 EN60335-2-44 Annex AD Ironers see note to item 33 2 X
E33.45 EN60335-2-45 Annex AD Portable heating tools See note to item 33 2 X
E33.47 EN60335-2-47 Annex AD Commercial electric boiling pans See note to item 33 2 X
E33.48 EN60335-2-48 Annex AD Commercial grillers and toasters See note to item 33 2 X
E33.49 EN60335-2-49 Annex AD Commercial electric hot cupboards See note to item 33 2 X
E33.50 EN60335-2-50 Annex AD Commercial electric bain-marie See note to item 33 2 X
E33.51 EN60335-2-51 Annex AD Stationary circulation pumps for heating and service water installations See note to item 33 2 X
E33.52 EN60335-2-52 Annex AD Oral hygiene appliances See note to item 33 2 X
E33.53 EN60335-2-53 Annex AD Sauna heating appliances See note to item 33 2 X
E33.54 EN60335-2-54 Annex AD Surface-cleaning appliances employing liquids See note to item 33 2 X
E33.55 EN60335-2-55 Annex AD Appliances for aquariums/garden ponds See note to item 33 2 X
E33.56 EN60335-2-56 Annex AD Projectors See note to item 33 2 X
E33.58 EN60335-2-58 Annex AD Commercial electric dishwashing machines See note to item 33 2 X
E33.59 EN60335-2-59 Annex AD Insect killers See note to item 33 2 X
E33.60 EN60335-2-60 Annex AD Whirlpool baths See note to item 33 2 X
E33.61 EN60335-2-61 Annex AD Thermal storage room heaters See note to item 33 2 X
E33.62 EN60335-2-62 Annex AD Commercial electric water boilers See note to item 33 2 X
E33.64 EN60335-2-64 Annex AD Commercial electric kitchen machines See note to item 33 2 X
E33.65 EN60335-2-65 Annex AD Air-cleaning appliances See note to item 33 2 X
E33.66 EN60335-2-66 Annex AD Water-bed heaters See note to item 33 2  
E33.67 EN60335-2-67 Annex AD Floor treatment and floor cleaning machines, for industrial and commercialuse See note to item 33 2 X
E33.68 EN60335-2-68 Annex AD Spray extraction appliances, for industrial and commercial use See note to item 33 2 X
E33.69 EN60335-2-69 Annex AD Wet and dry vacuum cleaners, for industrial and commercial use See note to item 33 2 X
E33.70 EN60335-2-70 Annex AD Milking machines See note to item 33 2 X
E33.71 EN60335-2-71 Annex AD Heating appliances for breeding/rearing animals See note to item 33 2 X
E33.72 EN60335-2-72 Annex AD Automatic machines for floor treatment, for industrial and commercialuse See note to item 33 2 X
E33.73 EN60335-2-73 Annex AD Fixed immersion heaters See note to item 33 2 X
E33.74 EN60335-2-74 Annex AD Portable immersion heaters See note to item 33 2 X
E33.75 EN60335-2-75 Annex AD Commercial dispensing appliances and vending machines See note to item 33 2 X
E33.76 EN60335-2-76 Annex AD Electric fence energizers See note to item 33 2 X
E33.77 EN60335-2-77 Annex AD Pedestrian controlled mains-operated lawnmowers See note to item 33 2 X
E33.78 EN60335-2-78 Annex AD Outdoor barbecues See note to item 33 2 X
E33.79 EN60335-2-79 Annex AD High pressure cleaners and steam cleaners, for industrial and commercialuse See note to item 33 2 X
E33.80 EN60335-2-80 Annex AD Fans See note to item 33 2 X
E33.81 EN60335-2-81 Annex AD Foot warmers and heating mats See note to item 33 2 X
E33.82 EN60335-2-82 Annex AD Service and amusement machines See note to item 33 2 X
E33.83 EN60335-2-83 Annex AD Heated gullies for roof drainage See note to item 33 2 X
E33.84 EN60335-2-84 Annex AD Toilets See note to item 33 2 X
E33.85 EN60335-2-85 Annex AD Garment and fabric steamers See note to item 33 2 X
E33.86 EN60335-2-86 Annex AD Electric fishing machines See note to item 33 2 X
E33.87 EN60335-2-87 Annex AD Animal stunning equipment See note to item 33 2 X
E33.88 EN60335-2-88 Annex AD Humidifiers for use with heating, ventilation or air conditioning systems See note to item 33 2 X
E33.89 EN60335-2-89 Annex AD Commercial refrigerating appliances See note to item 33 2 X
E33.90 EN60335-2-90 Annex AD Commercial microwave ovens See note to item 33 2 X
E33.91 EN60335-2-91 Annex AD Walk-behind and handheld lawn trimmers See note to item 33 2 X
E33.92 EN60335-2-92 Annex AD Pedestrian controlled mains-operated lawn scarifiers and aerators See note to item 33 2 X
E33.95 EN60335-2-95 Annex AD Drives for vertically moving garage doors for residential use See note to item 33 2 X
E33.96 EN60335-2-96 Annex AD Flexible sheet heating elements for room heating See note to item 33 2 X
E33.97 EN60335-2-97 Annex AD Drives for rolling shutters, awnings, blinds See note to item 33 2 X
E33.98 EN60335-2-98 Annex AD Humidifiers See note to item 33 2 X
E33.99 EN60335-2-99 Annex AD Commercial electric hoods See note to item 33 2 X
E33.101 EN 60335-2-101 Annex AD Vaporizers See note to item 33 2 X
E33.102 EN  60335-2-102 Annex AD Gas, oil and solid-fuel burning appliances having electrical connections See note to item 33 2 X
E33.103 EN 60335-2-103 Annex AD Drives for gates, doors and windows See note to item 33 2 X
E33.105 EN 60335-2-105 Annex AD Particular requirements for multifunctional shower cabinets See note to item 33 2 X
E33.106 EN 60335-2-106 Annex AD Particular requirements for heated carpets and for heating units for room heating installed under removable floor coverings See note to item 33 2 X
E33.108 EN 60335-2-108 Annex AD Particular requirements for electrolysers See note to item 33 2 X
E34 EN 60065 Annex Z Audio, video and similar electronic apparatus –
Safety requirements
See note to item 34 2 X
E35 EN60825-1 Annex AA Safety of laser products.
Part 1: Equipment classification and requirements
no 2 X
E36 EN 61210 Annex AE Flat quick-connect terminations for electrical copper
conductors
no 2 X
E37 EN60745-1 Annex AF Hand-held motor-operated electric tools - Safety -
Part 1: General requirements
Not for standalone ENEC certification 2 X
E37.1 EN60745-2-1 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-1: Particular requirements for drills and impact drills
no 2 X
E37.2 EN60745-2-2 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-2: Particular requirements for screwdrivers and impact wrenches
no 2 X
E37.3 EN60745-2-3 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-3: Particular requirements for grinders, polishers and disktype sanders
no 2 X
E37.4 EN60745-2-4 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-4: Particular requirements for sanders and polishers other than disktype
no 2 X
E37.5 EN60745-2-5 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-5: Particular requirements for circular saws
no 2 X
E37.6 EN60745-2-6 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-6: Particular requirements for hammers
no 2 X
E37.8 EN60745-2-8 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-8: Particular requirements for shears and nibblers
no 2 X
E37.9 EN60745-2-9 Annex AF Hand-held motor-operated electric tools - Safety -
Part 2-9: Particular requirements for tappers
no 2 X
E37.11 EN60745-2-11 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-11: Particular requirements for reciprocating saws (jig and sabresaws)
no 2 X
E37.12 EN60745-2-12 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-12: Particular requirements for concrete vibrators
no 2 X
E37.13 EN60745-2-13 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-13: Particular requirements for chain saws
no 2 X
E37.14 EN60745-2-14 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-14: Particular requirements for planers
no 2 X
E37.15 EN60745-2-15 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-15: Particular requirements for hedge trimmers
no 2 X
E37.17 EN60745-2-17 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-17: Particular requirements for routers and trimmers
no 2 X
E37.18 EN60745-2-18 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-18: Particular requirements for strapping tools
no 2 X
E37.19 EN60745-2-19 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-19: Particular requirements for jointers
no 2 X
E37.20 EN60745-2-20 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-20: Particular requirements for band saws
no 2 X
E37.21 EN60745-2-21 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-21: Particular requirements for drain cleaners
no 2 X
E37.22 EN60745-2-22 Annex AF Hand-heldmotor-operated electric tools - Safety -
Part 2-22: Particular requirements for cut-off machines
no 2 X
E38 EN61029-1 Annex AG Safety oftransportable motor-operated electric tools -
Part 1: General requirements
Not for standalone ENEC certification 2 X
E38.1 EN61029-2-1 Annex AG Safety oftransportable motor-operated electric tools -
Part 2-1: Particular requirements for circular saw benches
no 2 X
E38.4 EN61029-2-4 Annex AG Safety oftransportable motor-operated electric tools -
Part 2-4: Particular requirements for bench grinders
no 2 X
E38.5 EN61029-2-5 Annex AG Safety oftransportable motor-operated electric tools -
Part 2-5: Particular requirements for band saws
no 2 X
E38.8 EN61029-2-8 Annex AG Safety oftransportable motor-operated electric tools -
Part 2-8: Particular requirements for single spindle vertical moulders
no 2 X
E38.9 EN61029-2-9 Annex AG Safety oftransportable motor-operated electric tools -
Part 2-9: Particular requirements for mitre saws
no 2 X
E38.11 EN61029-2-11 Annex AG Safety oftransportable motor-operated electric tools -
Part 2-11: Particular requirements for combined mitre and bench saws
no 2 X
E39 EN 62133 Annex AH Secondarycells and batteries containing alkaline or other non-acid electrolytes -Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications no 2 X
E40 EN 60799 Annex AI Cord setsand interconnection cord sets See note to item 40 2 X
E41 EN 61535 Annex AK Installationcouplers intended for permanent connection in fixed installations no 2 X
E42 EN 62560 Annex AL Self-ballastedLED lamps > 50V no 1 X
E43.1 EN60252-1 Annex AM AC motor capacitors –Part 1: General – Performance, testing andrating – Safety requirements – Guidance for installation and operation no 2 X
E43.2 EN60252-2 Annex AM AC motor capacitors –Part 2: Motor start capacitors no 2 X
E44.1 EN60127-1 Annex AN Miniature fuses -Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links Not for standalone ENEC certification 2 X
E44.2 EN60127-2 Annex AN Miniature fuses -Part 2: Cartridge fuse-links no 2 X
E44.3 EN60127-3 Annex AN Miniature fuses -Part 3: Specification for sub-miniature fuse-links no 2 X
E44.4 EN60127-4 Annex AN Miniature fuses-Part 4: Universal modular fuse-links (UMF)-Through-hole and surface mount types no 2 X
E44.6 EN60127-6 Annex AN Miniature fuses -Part 6: Fuse-holders for miniature cartridge fuse-links no 2 X
E45.1 EN61810-1 Annex AO Electromechanical elementary relays -Part 1: General requirements no 2 X
E46 EN50131-1 Annex AP Intrusion and Hold-up Alarm Systems - System requirements no 2 X
E46.2 EN50131-2-2 Annex AP Intrusion and Hold-up Alarm Systems - Intrusion detectors - Passive infrared detectors no 2 X
E46.3 EN50131-2-3 Annex AP Requirements for microwave detectors no 2 X
E46.4 EN50131-2-4 Annex AP Requirements for combined passive infrared and microwavedetectors no 2 X
E46.5 EN50131-2-5 Annex AP Requirements for combined passive infrared and ultrasonic detectors no 2 X
E46.6 EN50131-2-6 Annex AP Opening contacts (magnetic) no 2 X
E46.7 EN50131-2-7-1 Annex AP Intrusion detectors - Glass break detectors (acoustic) no 2 X
E46.8 EN50131-2-7-2 Annex AP Intrusion detectors - Glass break detectors (passive) no 2 X
E46.9 EN50131-2-7-3 Annex AP Intrusion detectors - Glass break detectors (active) no 2 X
E46.10 EN50134-2 Annex AP Social Alarm systems – Trigger devices no 2 X
E47 EN50136-1 Annex AQ General requirements for alarm transmission systems no 2 X
E47.1 EN50136-2-1 Annex AQ General requirements for alarm transmission equipment no 2 X
E47.2 EN50136-2-2 Annex AQ Requirements for equipment used in systems using dedicated alarm paths no 2 X
E47.3 EN50136-2-3 Annex AQ Requirements for equipment used in systems with digital communicators using the public switched telephone network no 2 X
E47.4 EN50136-2-4 Annex AQ Requirements for equipment used in systems with voice communicators using the public switched telephone network no 2 X
E47.5 EN50131-4 Annex AQ Intrusion and Hold-up Alarm Systems - Warning devices no 2 X
E47.6 EN50131-5-3 Annex AQ Intrusion and Hold-up Alarm Systems – Requirements for interconnection equipment using radio frequency techniques no 2 X
E47.7 EN50134-5 Annex AQ Social Alarm systems - Interconnections and communications no 2 X
E48.3 EN50131-3 Annex AR Intrusion and Hold-up Alarm Systems - Control and indicating equipment no 2 X
E48.6 EN50131-6 Annex AR Intrusion and Hold-up Alarm Systems – Power supplies no 2 X
E48.7 EN50134-3 Annex AR Social Alarm systems - Trigger devices no 2 X
E49 EN50133-1 Annex AS Access control systems - System requirements no 2 X
E49.1 EN50133-2-1 Annex AS Access control systems - General requirements for components no 2 X
E49.7 EN50133-7 Annex AS Access control systems - Security applications - Application guidelines no 2 X
E49.11 EN60839-11-1 Annex AS Alarm and electronic security systems - Electronic access control systems - System and components requirements no 2 X
E50 EN 62776 Annex AT Double-cappedLED lamps designed to retrofit linear fluorescent lamps - Safety specifications See note to item 50 1 X
E51 EN62368-1 Annex AU Audio/video,information and communication technology equipment - Part 1: Safety requirements no 2 X
E60.1 EN60947-1 Annex AV Low-voltage switchgear and controlgear - Part 1: General rules   no 2 X
E60.7.4 EN60947-7-4 Annex AV Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors no 2 X

NOTES

*) The agreement is applicable to products complying with the indicated standards and with the limitations and/or modifications indicated in this column. The limitations take into account, as far as possible, the special national conditions and A-deviations applicable in the countries of the ENEC Agreement signatories.

**) The following definitions apply:

Manufacturer
A company with manufacturing capacity, situated at a stated location or stated locations, that carries out or controls such stages in the manufacture, assessment, handling and storage of a product that enables it to accept responsibility for continued compliance of the product with the relevant requirements and undertakes all obligations in that connection. There is no restriction regarding the country where the manufacturer or the manufacturing site of the product is located for ap-plying for an ENEC licence.

Location Testing Laboratory:
Testing of products will take place worldwide.

List of limitations

Item 1:

EN 60598-1 – Luminaires

  • clause 2.2 Class 0 luminaires are not in the scope of the Agreement;
  • clause 3.2 For luminaires to be connected directly to the supply the rated voltage shall be 230 V or a range including 230 V.
  • clause 3.3 Special national conditions concerning the labelling of the luminaire are to be fulfilled for luminaires for use in Denmark, as indicated in the annex to EN 60598 1.
  • clause 3.3 The Certification Body, granting the licence, shall check the correct wording of the mounting instructions, if any, In a language acceptable to it. The manufacturer shall take care of the correct wording in other required languages (with or without assistance of the Certification Body).
  • clause 5.2.1 Luminaires provided with a plug shall be equipped with one of the following types
    IEC 83
    - class I: luminaires - Standard sheets: C4
    - class II: luminaires - Standard sheets: C5*, C6
    *) Identical to EN 50075
    Luminaires for use in Great Britain:

    IEC 83
    - Class I: Standard sheets: B1, B2
    GENERAL NOTE: For Class I luminaires the plug may be in accordance with the National Standard Sheet of the country to which the luminaire will be marketed.
  • clause 5.2.2 Flexible cables and cords with PVC insulation are not accepted on luminaires intended for use outdoors.
Item 1.7:

EN 60598-2-7 - Portable luminaires for garden use

  • clause 7.4.1 Portable luminaires for garden use shall be of class II or III only.
    NOTE: This limitation is related to a special national condition in Denmark.
Item 1.22:

EN 60598-2-22 - Luminaires for emergency lighting

  • Spain: Special national conditions for Spain, as indicated in annex ZB to EN 60598-2-22 (see corrigendum of October 2007).
    • when checked satisfactorily to the above mentioned national conditions: “Este aparato cumple con los requisitos adicionales para los locales de pública concurrencia en España” (“This appliance has been checked satisfactorily to the additional regulatory requirements for public buildings areas in Spain”)
    • when not checked to the above mentioned national conditions: “En este aparato no se han comprobado los requisitos adicionales para los locales de pública concurrencia en España” (“This appliance has not been checked to the additional regulatory requirements for public buildings areas in Spain”)
Item 15:

EN 60570 - Electrical supply track systems for luminaires

  • clause 4.3 Track-systems shall exist of at least a track, supply connector, coupler and adapter.
  • clause 4.3 All components according to the manufacturers catalogue shall be subject to testing.
  • clause 4.3 Adapters, provided with socket outlets are not accepted, as the track-system is only intended for connection of luminaires.
  • clause 4.3 Multi-adapters as a single component are excluded from the ENEC mark, as the adapter manufacturer can not control the dimensions of the essential parts of the third party track.
  • clause 5 The catalogue shall not include any information about the use of the track-system or adaptor that is not controlled by the licensee.
  • clause 5 ENEC mark is only allowed on the tracks or the supply con¬nectors. ENEC mark on the single adapter is not allowed.
  • clause 5.5 Warnings according to sub clauses 5.5 and 5.6 respectively shall be given either on the track-system or the mounting instructions, delivered with the track-system.
    NOTE: Adapter interface components, not forming a fixed part with the luminaire can be accepted for ENEC mark if all relevant requirements of EN 60598-1 are fulfilled.
    Special attention is given to the fact that adapter interface components are not covered by EN 60570 and the luminaire standard EN 60598-1 does not give a defined testing program for these products.
Item 24:

EN 60998-1 - Connecting devices for low voltage circuits for household and similar purposes. Part 1: General requirements

EN 60998-2-1, 2 and 3 - Connecting devices for low voltage circuits for household and similar purposes. Part 2: Particular requirements

Scope: For components intended to be used only in appliances

Item 25:

EN 60999-1 - Connecting devices – Electrical copper conductors To be used only as an accessory to EN 60998

Item 29:

EN 50075 - Flat non-rewirable two-pole plugs, 2,5 A 250 V, with cord.

Any appliance fitted with a Europlug and intended for use in the UK shall carry a warning label stating: “Within the UK this appliance may only be used when supplied from a shaver supply unit in accordance with EN 61558-2-5 and must not to be connected to a UK mains socket.”

Item 33:

EN 60335 - Household and similar electrical appliances Limitations due to Special National Conditions and A-deviations as given in the respective standard apply.

Item 33:

EN 60065 - Audio, video and similar electronic apparatus – Safety requirements Limitations due to Special National Conditions and A-deviations as given in the standard apply.

Item 40:

EN 60799 – For cord sets, restricted to plug according to EN 50075 with a nominal current of 2.5A

Item 50:

EN 62776 - The lamp manufacturer shall put the following sentence in the instruction of use: “Compatibility of this lamp with the luminaire shall be checked with the luminaire manufacturer”