Certification Body Name:
IMQ - ISTITUTO ITALIANO DEL MARCHIO DI QUALITA' S.p.A.

Back to members

 

CB Acronym: IMQ ID #: 03
Contact person: Dr. Mauro Casari
Address 1: Via Quintiliano 43
City: Milano Postal code: I - 20138
State / Province: IT Country: Italy
Address 2:
Email address: mauro.casari@imq.it Url: http://www.imq.it
Business phone: +39 02 5073 707 Fax:
Mobile phone:  
Deadline for the next Re-assessment: 2024-11-03
Comments:

Aditionnal contacts informations

Mr. Matteo Raismondi

Email address: matteo.raimondi@imq.it
Business phone: +39 02 5073 707 Fax:
Mobile phone:
 

 

 

ENEC Plus
CB IMQ - Product Category
LITE
Laboratory Name Acronyme Country City
Istituto Italiano del Marchio di Qualita S.p.A. IMQ Italy Milano
E-CTF type E-CTF Laboratory Name E-CTF Address E-CTF Country Standards Covered Registration date Latest Revision date Report Ref.
E-CTF-2 3F FILIPPI S.p.A. (PROVE E COLLAUDI) Via del Savena, 28 IT-40065 Pianoro Bologna (BO) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 8.2.7, 9.2.10, 9.2.11, 9.3.1, 12.5.1e) Annex C Fig. C3, 12.7.2, 13.2.1, 13.3.1, 13.3.2, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.5, Annex C, 22.18, 22.20 [Type of operation: centrally supplied emergency luminaires only]); EN IEC 60598-2-22:2022 (All clauses except 22.17.5, Annex C, 22.18, 22.20 [Type of operation: centrally supplied emergency luminaires only]); EN 60598-2-24:2013; EN IEC 62031:2020 + A11:2021 (All clauses except 10, 12.1, 16, 17, 18, 20, 21, Annex D) [EMC] EN IEC 55015:2019 + A11:2020 (All clauses except: - Insertion loss measurement - Radiated disturbance measurements in semi-anechoic chamber (frequency range 30 MHz to 300 MHz covered by independent method – CDNE-method) (# 9) - Conical metal housing for single capped lamps. Electrical power supply interface disturbance measurements.); EN IEC 61547:2023 (All clauses except: - Continuous radiated radio frequency disturbance (# 5.3) - Power frequency magnetic fields (# 5.4) - Continuous radio frequency disturbance (# 5.6)); EN IEC 61000-3-2:2019 + A1:2021; EN 61000-3-3:2013 + A1:2019 + A2:2021 2007-03-06 2024-03-06 IMQ-078/E-CTF2 Issue No: 3
E-CTF-2 A.A.G. STUCCHI S.r.l. unico socio [Prod. Cat.: INST - LITE] Via IV Novembre, 30/32 IT-23854 Olginate Lecco (LC) Italy [INST] EN 60998-1:2004 (All clauses except 12.3); EN 60998-2-1:2004 (All clauses except 12.3); EN 60998-2-2:2004 (All clauses except 12.3); EN 61984:2009 (All clauses except 7.3.7, 7.3.9, 7.3.10, 7.3.13, 7.3.14, 7.4.2) [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.3); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.13, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 9.3); EN 60400:2017 + A1:2021 (All clauses except 10.2 (only for soldering lugs)); EN 60838-1:2016 + A1:2017 + A11:2021 + A2:2021 (All clauses except 8.2 (only for soldering lugs)); EN 60570:2003 + A1:2017 + A2:2020 (All clauses except 14) 2006-11-23 2023-12-14 IMQ-071/E-CTF2 Issue No: 1
E-CTF-2 AB PLAST S.r.l. Via Fura, 38/A IT - 25125 Brescia (BS) Italy [INST] EN 60669-1:2018 (All clauses except 15.2.2 (for degrees of protection higher than IPX4), 15.2.3 (for degree of protection higher than IPX6)) 2021-11-25 2022-11-25 IMQ-402/E-CTF2 Issue No: 1
E-CTF-2 ABB S.p.A. (LABORATORIO PROVE ABB) [Prod. Cat.: EMC] Viale dell'Industria, 18 IT-20010 Vittuone Milano (MI) Italy [EMC] EN 61000-4-2:2009; EN 61000-4-4:2012; EN 61000-4-5:2014 + A1:2017; EN 61000-4-6:2014; EN 61000-4-8:2010 (Accepted clauses of only continuous field up to 30 A/m); EN 61000-4-9:2016; EN IEC 61000-4-11:2020 + AC:2020 (All clauses (single-phase systems only)); EN 61000-4-16:2016 (All clauses except short duration disturbances); EN 61000-4-19:2014 (All clauses except Rectangular Modulation); EN 61000-4-20:2010; EN 55011:2016 + A1:2017 + A11:2020 (Accepted sub-slause 8.2 (Conducted Emissions)); EN 55014-1:2017 + A11:2020 (All clauses except 5.3.2, 5.3.3, 5.4.2); EN IEC 55015:2019 + A11:2020; EN 55032:2015 + A1:2020 + A11: 2020 (Accepted Annex A.3 (Conducted Emissions)); EN IEC 61000-6-1:2019 (All clauses except 1.1 Table 1 (Magnetic Field)); EN IEC 61000-6-2:2019 (All clauses except 1.1 Table 1 (Magnetic Field)); EN 61000-6-3:2007 + A1:2011 (All clauses except tests belonging to IEC 61000-3 series); EN IEC 61000-6-4:2019; EN 61326-1:2013 (All clauses except Radiated emission measurement and Electromagnetic field); EN IEC 61326-1:2021 (All clauses except Radiated emission measurement and Electromagnetic field); EN 61557-12:2008 (All clauses except radiated emission measurement and Electromagnetic field); EN IEC 61557-12:2022 (All clauses except radiated emission measurement and Electromagnetic field); EN 61543:1995 + A11:1995 + A12:2005 + A2:2006 (All clauses except Ref. T 2.5 of Tab. 2 and radiated emission measurements); EN IEC 61523:2023 + A11:2023 (All clauses except Radiated high-frequency phenomena and Radiated emission measurements); EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted sub-clause 8.4.1 (except 8.4.1.2.3, 8.4.1.2.7)); EN 60947-2:2017 (Accepted Annex J (except J.2.3, J.3.3)); EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61008-2-1:1994 + A11:1998 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-2-1:1994 + A11:1998 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 62423:2012 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 62606:2013 + A1:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 60669-2-1:2004 + A1:2009 + A12:2010 (Accepted clause 26 (except 26.1.5, 26.1.7)); EN IEC 60669-2-1:2022 + A11:2022 (Accepted clause 26 (except 26.1.5, 26.1.7)); EN 60669-2-5:2016 (Accepted clause 26 (except 26.2.6, 26.2.8, 26.3.1, 26.3.4)); EN 50491-5-1:2010 (All clauses except 6.2.2, 6.2.6, 6.3.2, 6.3.3)); EN 50491-5-2:2010 (All clauses except 6.2.2, 6.2.6, 6.3.2, 6.3.3)); EN 50130-4:2011 + A1:2014; ETSI EN 301 489-1 V2.2.3 (All clauses except Radiated emission measurement and Electromagnetic field); ETSI EN 301 489-3 V2.1.1 (All clauses except radiated emission measurement and Electromagnetic field); ETSI EN 301 489-17 V3.2.4 (All clauses except radiated emission measurement and Electromagnetic field); CLC/TR 50579:2012; EN 50470-1:2006 + A1:2018 (Accepted clauses 6.3.2, 6.3.3, 6.3.4, 7.3, 7.4.4, 7.4.5, 7.4.7, 7.4.8, 7.4.9, 7.4.13 (limited to conducted tests)); EN 50470-3:2006 + A1:2018 (Accepted clauses 8.1, 8.4, 8.7.2, 8.7.3, 8.7.4, 8.7.5.2, 8.7.5.3, 8.7.5.4, 8.7.6, 8.7.7.2, 8.7.7.3, 8.7.7.4, 8.7.7.5, 9.7.7.7, 8.7.7.8, 8.7.7.9, 8.7.9.3, 8.7.9.4, 8.7.10, 9, 10)); EN 62059-32-1:2012; EN IEC 62052-11:2021 + A11:2022 (Accepted clause 9 (except 9.3.2, 9.3.4, 9.3.5, 9.3.8 - Triangular Modulation, 9.3.12, 9.3.13, 9.3.14 - Radiated Emission)); EN 63024:2018 (Accepted clause 22 (except Radiated Emission measurement and Electromagnetic field)) 2017-06-09 2023-06-06 IMQ-308/E-CTF2 Issue No: 1
E-CTF-3 ABB S.p.A. (LABORATORIO PROVE ABB) [Prod. Cat.: INST - PROT (Protection Devices)] Viale dell'Industria, 18 IT-20010 Vittuone Milano (MI) Italy [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 9.4.2.3); EN IEC 60947-1:2021 (All clauses except 9.4.2.3); EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses except Annex J); EN 60947-2:2016 + A1:2020 (All clauses except Annex J.2.3); EN 60947-3:2009 + A1:2012; EN IEC 60947-3:2021 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 61008-2-1:1994 + A11:1998 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 61009-2-1:1994 + A11:1998 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 62423:2012 + A11:2021 + A12:2022 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 62606:2013 + A1:2017 (All clauses except Test Sequence I (only IEC 61543 Table 5 - T2.5)); EN 60269-1:2007 + A1:2009 + A2:2014; HD 60269-2:2013; HD 60269-3:2010 + A1:2013 2003-06-19 2023-07-19 IMQ-019/E-CTF3 Issue No: 1
E-CTF-3 ARISTON S.p.A. (Laboratorio Prove) Via Pascoli, 1 IT-60044 Fabriano Ancona (AN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 19.11.4 (EMP), Annex F, Annex G, Annex H, Annex K, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 19.11.4 (EMP), Annex F, Annex G, Annex H, Annex K, Annex R, Annex T, IEC/EN 62233 (EMF)); EN 60335-2-21:2003 + A1:2005 + A2:2008; EN 60335-2-21:2021 + A1:2021; EN 60335-2-35:2002 + A1:2007 + A2:2011; EN 60335-2-35:2016 + A1:2019 + A2:2021 (All clauses except Annex R); EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 + A2:2009 + A13:2012 1991-04-08 2023-11-15 IMQ-012/E-CTF3 Issue No: 2
E-CTF-2 BAXI S.p.A. (R&D LABORATORY) Via Trozzetti, 20 IT-36061 Bassano del Grappa Vicenza (VI) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A14:2019 + A1:2019 + A2:2019 + A15:2021 (All clauses except 19.11.4 (EMP), 29, 30.1, 30.2); EN 60335-2-102:2016; EN 60529:1991 + A1:2000 + A2:2013 (All clauses (only for protection degrees IPX4, IPX5, IPXXD)) 1997-07-18 2023-05-18 IMQ-002/E-CTF2 Issue No: 1
E-CTF-2 BEGHELLI S.p.A. (Laboratorio Certificazione Beghelli) Via Mozzeghine, 13/15 IT-40053 Valsamoggia - Località Monteveglio Bologna (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 5.2.10, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 10.3.1, 12.5.1e) Annex C Fig. C3, 13.3.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 5.2.10, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 10.3.1, 12.5.1e) Annex C Fig. C3, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-8:2013 (All clauses except 8.11.4.1, 8.16.1); EN 60598-2-22:2014 + A1:2020; EN IEC 60598-2-22:2022; EN 60598-2-24:2013; EN 61347-1:2015 + A1:2021 (All clauses except 14.6, 17, 18.2, 18.4, 18.5, 19, Annex B (B.9.5)); EN 61347-2-7:2012 + A1:2019 + A2:2022 (All clauses except 4.4.5 of IEC 62034 (prescribed in Annex K)); EN 61347-2-11:2001 + A1:2019; EN 61347-2-13:2014 + A1:2017; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1.g), 18, 19); EN IEC 62031:2020 + A11:2021 (All clauses except 21, Annex D) 2005-10-10 2023-06-22 IMQ-058/E-CTF2 Issue No: 2
E-CTF-2 BOCCHIOTTI S.p.A. Via Pian Masino, 109 IT-16011 Arenzano Genova (GE) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A11:2011; EN 50085-2-2:2008 (All clauses except 14.101); EN 50085-2-3:2010; EN 50085-2-4:2009; EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010; EN IEC 61386-21:2021 + A11:2021; EN 61386-22:2004 + A11:2010; EN IEC 61386-22:2021 + A11:2021; EN 61386-23:2004 + A11:2010; EN IEC 61386-23:2021 + A11:2021; EN 60670-1:2005 + A1:2013 (All clauses except 19); EN IEC 60670-1:2021 + A11:2021 (All clauses except 19); EN 60670-22:2006; EN 60670-23:2008; EN 60670-24:2013; EN 62208:2011 (All clauses except 9.12, 9.13) 2005-10-10 2023-04-17 IMQ-056/E-CTF2 Issue No: 1
E-CTF-2 BONFERRARO S.p.A. Via Oberdan, 57 IT-37060 Bonferraro di Sorgà Verona (VR) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 19.11.4 (EMP), Annex R; Annex T); EN 60335-2-5:2015 + A11:2019 + A1:2020 [MEAS] EN 61010-1:2010 + A1:2019 (All clauses except 11.6, 12.2.1, 12.2.2, 12.3, 12.4, 12.5.2, 12.6, 13.2.3, 14.8, Annex H); EN 61010-2-040:2015 (All clauses except 7.106, 12.3, 13.1, 13.101); EN IEC 61010-2-040:2021 (All clauses except 7.106, 12.3, 13.1, 13.101) 2001-05-08 2022-11-21 IMQ-004/E-CTF2 Issue No: 1
E-CTF-2 BRAHMA S.p.A. (Omologation and testing laboratory (LOM)) Via del Pontiere, 31 IT-37045 Legnago (VR) Italy [CONT] EN 60730-1:2000 + A12:2003 + A1:2004 + A13:2004 + A14:2005 + A16:2007 + A2:2008 (All clauses except 18, 21, 22, 23, 28, H26.10, H26.12.3, H26.16); EN 60730-1:2011 (All clauses except 18, 21, 22, 23, 28, H26.10, H26.12.3, H26.16); EN 60730-2-5:2002 + A1:2004 + A11:2005 + A2:2010; EN 60730-2-5:2015 2017-09-08 2023-05-05 IMQ-233/E-CTF2 Issue No: 1
E-CTF-3 BTICINO S.p.A. (SALA PROVE BTICINO) Viale L. Borri, 231 IT-21100 Varese Varese (VA) Italy [INST] EN 50085-1:2005; EN 50085-2-1:2006 + A1:2011; EN 50085-2-3:2010; EN 50085-2-4:2009; EN 61242:1997 + A1:2008; EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 8, 24.2); EN 60309-2:1999 + A1:2007 + A2:2012 (All clauses except 8, 24.2); EN 50250:2002 (All clauses except 8); EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-1:2004 + A1:2009 + A12:2010; EN 50428:2005 + A1:2007 + A2:2009 (All clauses except 26.2.3, 26.2.4); EN 60669-2-2:2006; EN 60669-2-3:2006; EN 60669-2-4:2005; EN 60669-2-5:2016 (All clauses except 26.2.3, 26.2.4); EN 62080:2009 + A2:2015; EN 62094-1:2003 + A11:2003; EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN IEC 60670-1:2021 + A11:2021; EN 60670-22:2008; EN 60670-24:2013; EN 61386-1:2008 + A1:2019 (All clauses except 13.1.3.2); EN 61386-21:2004 + A11:2010; EN IEC 61386-21:2021 + A11:2021 (All clauses except 13.1.3.2); EN 61386-22:2004 + A11:2010; EN IEC 61386-22:2021 + A11:2021 (All clauses except 13.1.3.2); EN 61386-23:2004 + A11:2010; EN IEC 61386-23:2021 + A11:2021 (All clauses except 13.1.3.2); EN 62444:2013 [POW] EN 62019:1999 + A1:2003 + A11:2005 + A12:2014; 2004; EN 60439-1:1999 + A1:2004; EN 61439-1:2011; EN 61439-2:2011; EN 60947-1:2007 + A1:2011 + A2:2014; EN IEC 60947-1:2021; EN 60947-2:2006 + A1:2009 + A2:2013; EN 60947-2:2017; EN 60947-3:2009 + A1:2012 + A2:2015; EN IEC 60947-3:2021; EN 60947-5-1:2004 + A1:2009 [CONT] EN 60934:2001 + A1:2007 + A2:2013 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014; EN 61008-2-1:1994 + A11:1998; EN 61009-1:2012 + A1:2014 + A2:2014; EN 61009-2-1:1994 + A11:1998; EN 62423:2012; EN 50557:2011; EN 61643-11:2012 + A11:2018 [EMC] EN 61543:1995 + A11:2003 + A12:2005 + A2:2006 2006-03-16 2023-05-04 IMQ-060/E-CTF3 Issue No: 2
E-CTF-2 BTICINO S.p.A. (SALA PROVE BTICINO) [Prod. Cat.: INST] Strada della Guasca, 201 IT-15122 Spinetta Marengo Alessandria (AL) Italy [INST] EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010 (Accepted clause 13.1.3.2); EN IEC 61386-21:2021 + A11:2021 (Accepted clause 13.1.3.2); EN IEC 61386-22:2021 + A11:2021 (Accepted clause 13.1.3.2); EN IEC 61386-23:2021 + A11:2021 (Accepted clause 13.1.3.2); EN 61537:2007 2007-12-31 2023-11-16 IMQ-206/E-CTF2 Issue No: 1
E-CTF-3 CANDY HOOVER GROUP S.r.l. (EMC/LVD Washing Lab) Via Comolli, 16 IT-20861 Brugherio Monza-Brianza (MB) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 19.11.4.2); EN 60335-2-5:2015 + A11:2019 + A1:2020; EN 60335-2-7:2010 + A1:2013 + A11:2013 + A2:2019; EN 60335-2-11:2010 + A11:2012 + A1:2015 + A2:2018 (All clauses except Annex BB); EN 61770:2009 + A11:2018 + A1:2019 + A12:2022 (All clauses except 8, 9) [EMC] EN 62233:2008 2005-01-01 2023-10-18 IMQ-005/E-CTF3 Issue No: 2
E-CTF-2 Cariboni Group S.p.A. Via della Tecnica, 19 IT-23875 Osnago Lecco (LC) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.4.5, 4.13.6, 4.14.1, 4.14.2, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.9, 9.3.1, 12.7.2, 13.3.1, 13.3.2, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.13.6, 4.14.1, 4.14.2, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 12.7.2, 13.3.1, 13.3.2, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60598-2-24:2013; EN 62031:2008 + A1:2013 + A2:2015 (All clauses except 5.5, 7.1g), 8, 11, 17, 18, 19, Annex A); EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2g), 7, 10, 12.1, 16, 17, 18, 20, 21, Annex A, Annex D); EN 62262:2002 All clauses [Test Eha (pendulum hammer), Test Ehb (Spring hammer) and Test Ehc (Vertical hammer) according to IEC/EN 60068-2-75:2014)] 2018-04-09 2023-05-19 IMQ-045/E-CTF2 Issue No: 2
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio CAFFE’) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-14:2006 + A1:2008 + A11:2012 + A12:2016; EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021; EN 60335-2-75:2004 + A11:2006 + A1:2005 + A2:2008 + A12:2010 (All clauses except 15.1.1, Annex AA); EN IEC 60335-2-75:2023 + A11:2023 + A1:2023 + A2:2023 (All clauses except 15.1.1, Annex AA) 2006-02-08 2023-09-26 IMQ-066/E-CTF2 Issue No: 1
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio COMFORT) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-30:2009 + A11:2012 + A1:2020 + A12:2020 + A13:2022 + A2:2022; EN 60335-2-43:2003 + A1:2006 + A2:2008; EN IEC 60335-2-43:2020 + A11:2020; EN 60335-2-65:2003 + A1:2008 + A11:2012 + A12:2022 + A2:2022 (All clauses except 32, Annex AA); EN 60335-2-80:2003 + A1:2004 + A2:2009 2005-07-05 2023-10-24 IMQ-029/E-CTF2 Issue No: 1
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio COTTURA) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48, Annex N, Annex R, Annex T); EN 60335-2-9:2003 + A1:2004 + A2:2006 + A12:2007 + A13:2010; EN IEC 60335-2-9:2023 + A11:2023; EN 60335-2-13:2010 + A11:2012 + A1:2019; EN 60335-2-15:2016 + A11:2018 + A1:2021 + A2:2021 + A12:2021 2006-02-08 2023-11-14 IMQ-067/E-CTF2 Issue No: 1
E-CTF-2 DE’ LONGHI APPLIANCES s.r.l. (Laboratorio STIRO & PULIZIA) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-2:2010 + A11:2012 + A1:2013 (All clauses except 21); EN 60335-2-3:2016 + A1:2020; EN 60335-2-85:2003 + A1:2008 + A11:2018 + A2:2020 2006-07-11 2023-09-26 IMQ-096/E-CTF2 Issue No: 2
E-CTF-2 DISANO ILLUMINAZIONE S.p.A. (Laboratorio Misure e Prove) Via Scaldasole, 8 IT-27020 Dorno Pavia (PV) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.11.6, 4.13.4, 4.13.6, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.3, 9.3.1, 12.7.2, 13.3.1, 13.4.1); EN IEC 60598-1:2021 (All clauses except 4.4.4, 4.11.6, 4.13.4, 4.13.6, 4.14.3, 4.18.1, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 12.7.2, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.2.1, 13.6.2.2); EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.5 Annex C); EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2 g), 7, 10, 16, 17, 18, 20, 21, Annex A, Annex D); EN 62262:2002 - IEC TR 62696:2011 (All clauses [Test Ehb (Spring hammer) and Test Ehc (Vertical hammer) according to IEC/EN 60068-2-75:2014)] [EMC] EN 61547:2009 (All clauses except 5.2, 5.3, 5.4, 5.6); EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55015:2013 + A1:2015 (All clauses except 7, 8.1.2, 8.1.3, 9.2) 2005-08-02 2023-07-28 IMQ-037/E-CTF2 Issue No: 1
E-CTF-2 DUCATI ENERGIA S.p.A. Via M.E. Lepido, 182 IT-40132 Bologna Bologna (BO) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.15, 5.16); EN 60831-1:2014 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-2:2014 (Accepted clauses 17, 18, 19) 2005-11-22 2022-11-07 IMQ-080/E-CTF2 Issue No: 1
E-CTF-2 ELECTROLUX PROFESSIONAL S.p.A. (Cooking Laboratory) Viale Treviso, 15 IT-33170 Pordenone Pordenone (PN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 + A14:2019 + A1:2019 + A2:2019 + A15:2021 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex E, Annex F, Annex G, Annex H, Annex K, Annex N, Annex R, Annex T); EN 60335-2-6:2015 (All clauses except 22.110, 22.111, 30, 32.101); EN 60335-2-36:2002 + A1:2004 + A2:2008 + A11:2012; EN 60335-2-37:2002 + A1:2008 + A11:2012; EN 60335-2-38:2003 + A1:2008; EN 60335-2-39:2003 + A1:2004 + A2:2008; EN 60335-2-42:2003 + A1:2008 + A11:2012; EN 60335-2-47:2003 + A1:2008 + A11:2012; EN 60335-2-48:2003 + A1:2008 + A11:2012; EN 60335-2-50:2003 + A1:2008; EN 60335-2-64:2000 + A1:2002; EN 60335-2-90:2006 + A1:2010; EN 60335-2-102:2016 (All clauses except 8.101) 2010-09-30 2022-10-20 IMQ-199/E-CTF2 Issue No: 1
E-CTF-2 ELECTROLUX PROFESSIONAL S.p.A. (Refrigeration Laboratory) Viale Treviso, 15 IT-33170 Pordenone Pordenone (PN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15, 19.11.4 (EMP), 21.2, 22.48, 29.2.1, 30.1, 30.2, Annex N, Annex T); EN 60335-2-89:2010 + A1:2016 + A2:2017 (All clauses except 15.102, 22.103, 22.104, 22.106, 22.107, 22.108) 2019-02-28 2022-11-21 IMQ-353/E-CTF2 Issue No: 1
E-CTF-2 ELETTROTECNICA ROLD S.r.l. Via della Merlata, 1 IT-20014 Nerviano Milano (MI) Italy [CONT] EN 60730-1:2011 (All clauses except 23, 26, Annex H); EN 60730-1:2016 + A1:2019 + A2:2022 (All clauses except 23, 26, Annex H); EN 60730-2-12:2006 + A11:2008 (All clauses except 23, 26, Annex H); EN IEC 60730-2-12:2019 (All clauses except 23, 26, Annex H); EN IEC 60730-2-14:2019 + A1:2022 + A2:2021 (All clauses except 23, 26, Annex H) [INST] EN IEC 61058-1:2018 (All clauses except 10.4, 14.1, 14.2, 19.2.4, 19.2.5, 23, 25); EN 61058-1-1:2016 (All clauses except 23) 2005-07-07 2023-06-28 IMQ-031/E-CTF2 Issue No: 1
E-CTF-2 EMBRACO SLOVAKIA s.r.o.(Electrical Laboratory) Odorínska Cesta, 2 SK-05201 Spi?ská Nová Ves Slovakia [HOUS] EN 60335 1:2012 + A11:2014 + A13:2017 (Accepted clauses: 7, 13.3, 16, 19 (except 19.11.4), 22.7, 22.9, 24.5, 30.1); EN 60335-2-34:2013 (Accepted clauses: 7, 13.3, 16, 19 (except 19.11.4), 22.7, 22.9, 22.101, 24.5, 30.1, Annex AA) 2007-08-01 2021-06-09 IMQ-116/CTF2-B
E-CTF-2 EVOCA S.p.A. (Laboratorio Ricerca e Sviluppo) Via Roma, 24 IT-24030 Valbrembo Bergamo (BG) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15.1, 19.11.4, 21.1, 22.3, 22.12, 22.32, 22.48, 23.3, 25.14, 26.3, 28.1, 29.2, 30, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4, 22.3, 22.12, 22.32, 22.48, 23.3, 25.14, 26.3, 28.1, 29.2 / Annex N, 30, Annex R, Annex T); EN 60335-2-24:2010 + A1:2019 + A2:2019 + A11:2020 (Accepted clauses 7, 10, 11, 19, 22.104, 22.105, 22.112, 22.113, 22.114, 22.115, 24, Annex AA); EN IEC 60335-2-24:2022 + A11:2022 (Accepted clauses 7, 10, 11, 19, 22.104, 22.105, 22.112, 22.113, 22.114, 22.115, 24, Annex AA); EN 60335-2-75:2004 + A1:2005 + A11:2006 + A2:2008 + A12:2010 (All clauses except 15.1.1, 22.47); EN IEC 60335-2-75:2023 + A1:2023 + A2:2023 (All clauses except 15.1.1) 2018-01-10 2026-06-16 IMQ-143/E-CTF2 Issue No: 3
E-CTF-2 FABER S.p.A. (R&D Laboratory) Viale XIII Luglio, 160 IT-60044 Fabriano Fabriano (AN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 + A16:2023 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-2-6:2015 + A1:2020 + A11:2020 (All clauses except 11.3 (probe figure 104), 22.110, 22.111, 29.3 (test probe 41 of IEC 61032)); EN 60335-2-31:2014 + A1:2023 + A11:2023 + A2:2023 2006-03-24 2024-01-26 IMQ-093/E-CTF2 Issue No: 3
E-CTF-2 FANTON S.p.A. Viale dell’Industria, 8/10IT-35026 ConselvePadova (PD) Italy [INST] EN 61242:1997 + A1:2008 + A2:2016 + A13:2017 2005-09-22 2022-10-01 IMQ-044/E-CTF2 Issue No: 1
E-CTF-2 FINDER S.p.A. Via Drubiaglio, 14 IT-10040 Almese Torino (TO) Italy [INST] EN 60669-1:2018 (All clauses except 15.2, 20, 24.2, 26); EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 15.2, 20, 24.2, 26); EN IEC 60669-2-1:2022 + A11:2022 (All clauses except 15.2, 20, 24.2, 26); EN 60669-2-2:2006 (All clauses except 15.2, 20, 24.2, 26) [CONT] EN 61810-1:2015 + A1:2020 (All clauses except 13); EN 61810-3:2015; EN 61095:2009 (All clauses except 9.3.3.4.1 item b (Impulse withstand voltage test), 9.3.4); EN 60730-1:2016 + A1:2019 + A2:2022 (Accepted clauses 13, 14, 16, 17, Annex U) 2006-02-21 2023-03-23 IMQ-068/E-CTF2 Issue No: 2
E-CTF-2 ELBA ITALY S.p.A. (Laboratorio Ricerca e Sviluppo) [Former: FISHER & PAYKEL APPLIANCES ITALY S.p.A. (Laboratorio Ricerca e Sviluppo)] Via Fabbian Matteo, 7 IT-31030 Borso del Grappa Treviso (TV) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 19.11.4 (EMP), 30, Annex E, Annex N); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021 (All clauses except 19.11.4 (EMP), 30, Annex E, Annex N); EN 60335-2-6:2015 + A11:2020 + A1:2020 (All clauses except 22.110, 22.111, 29, 30.1, 30.2, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2009-03-31 2022-11-10 IMQ-150/E-CTF2 Issue No: 2
E-CTF-2 FLOS S.p.A. Via Angelo Faini, 2 IT-25073 Bovezzo Brescia (BS) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.13.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 13.3.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN IEC 60598-2-23:2021; EN 60598-2-24:2013 2005-09-22 2024-04-10 IMQ-043/E-CTF2 Issue No: 2
E-CTF-3 GEWISS S.p.A. [Cenate Sotto] Via A. Volta, 1 IT-24069 Cenate Sotto Bergamo (BG) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A1:2011; EN 50085-2-3:2010; EN 61386-1:2008 (All clauses (only for accessories)); EN 61386-21:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-22:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-23:2004 + A11:2010 (All clauses (only for accessories)); EN 61386-24:2010 (All clauses (only for accessories)); EN 60309-1:1999 + A1:2007 + A2:2012; EN IEC 60309-1:2022; EN 60309-2:1999 + A1:2007 + A2:2012; EN IEC 60309-2:2022; EN 60309-4:2007 + A1:2012; EN IEC 60309-4:2022; EN 50250:2002 + A1:2015; EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 26); EN IEC 60669-2-1:2022 + A11:2022 (All clauses except 26); EN 60669-2-2:2006 (All clauses except 26); EN 60669-2-3:2006 (All clauses except 26); EN 60669-2-4:2005; EN 62094-1:2003 + A11:2003; EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN 60670-22:2006; EN 60670-24:2013; EN 62208:2011; EN 61984:2009 (All clauses except 7.3.14) [POW] EN 60947-1:2007 + A1:2011 + A2:2014; EN IEC 60947-1:2021; EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses except Annex J); EN 60947-2:2017 (All clauses except Annex J); EN 60947-3:2009 + A1:2012 + A2:2015; EN IEC 60947-3:2021; EN 60947-5-1:2017; EN 61439-1:2011; EN IEC 61439-1:2021; EN 61439-2:2011; EN IEC 61439-2:2021; EN 61439-3:2012; EN 61439-4:2013; EN 61439-5:2015; EN 61439-6:2012; EN 62019:1999 + A1:2003 + A11:2005 + A12:2014 [CONT] EN 61095:2009 [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except test sequences H, I, J); EN 61008-2-1:1994 + A11:1998 (All clauses except test sequences H, I, J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses except test sequences H, I, J); EN 61009-2-1:1994 + A11:1998 (All clauses except test sequences H, I, J); EN 62423:2012 + A11:2021 + A12:2022n(All clauses except test sequences H, I, J); EN 63024:2018 (All clauses except test sequence G) [ELVH] EN 62196-1:2014 (All clauses except 26.4); EN 62196-2:2017 (All clauses except 26.4); EN IEC 61851-1:2019 2001-09-12 2023-10-20 IMQ-008/E-CTF3 Issue No: 3
E-CTF-3 GEWISS S.p.A. [Cenate Sopra] Via Provinciale, 61 IT-24060 Cenate Sopra Bergamo (BG) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.13.4, 4.14.1, 4.20, 4.24 / Annex P, 4.26, 9.2.9); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.14.1, 4.20, 4.24 / Annex P, 4.26); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-22:2014 + A1:2020 (All clauses except 22.17.1 Annex C); EN 60598-2-24:2013; EN 61347-1:2015 + A1:2021; EN 61347-2-7:2012 + A1:2019 + A2:2022; EN 61347-2-13:2014 + A1:2017; EN IEC 62031:2020 + A11:2021 (All clauses except 21); EN 62262:2002 + A1:2021 - IEC TR 62696:2011 (Accepted test method: Eha: Pendulum Hammer) 2020-07-07 2024-02-06 IMQ-374/E-CTF3 Issue No: 2
E-CTF 2 GEWISS S.p.A. (Laboratorio di Compatibilità Elettromagnetica) [Prod. Cat.: EMC] Via A. Volta, 1 IT-24069 Cenate Sotto Bergamo (BG) Italy [EMC] EN 50491-5-2:2010 (Excluded radiated immunity and emission test); EN 50491-5-3:2010 (Excluded radiated immunity and emission test); EN 50557:2011 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 55014-1:2006 + A1:2009 + A2:2011 (Excluded radiated emission test); EN 55014-1:2017 (Excluded radiated emission test); EN 55014-2:2015 (Excluded radiated immunity test); EN 55015:2013 + A1:2015 (Excluded radiated emission test); EN 60669-2-1:2004 + A1:2009 + A12:2010 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 60669-2-5:2016 (Accepted clause 26 (excluded radiated immunity and emission test)); EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted sub-clause 7.3 (excluded radiated emission test and only sub-clause 8.4.1 except 8.4.1.2.3)); EN 60947-2:2006 + A1:2009 + A2:2013 (Accepted sub-clause 7.3 (excluded radiated emission test and only Annex J except J.2.3)); EN 60947-2:2017 (Accepted sub-clause 7.3 (excluded radiated emission test and only Annex J except J.2.3)); EN 61000-3-2:2014; EN 61000-3-3:2013; EN 61000-6-1:2007 (Excluded radiated immunity test); EN 61000-6-2:2005 (Excluded radiated immunity test); EN 61000-6-3:2007 + A1:2011 (Excluded radiated emission test); EN 61000-6-4:2007 + A1:2011 (Excluded radiated emission test); EN 61543:1995 + A11:1995 + A12:2005 + A2:2006 (Accepted clauses 4, 5 (except clause 4 Ref. T 2.5 of Tab. 5)); EN 61547:2009 (Excluded radiated immunity test); EN 62493:2015 (Excluded radiated immunity test); EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 (Accepted Annex H (except radiated emissions), Annex I (except Table 5 - T 2.5), Annex J) 2017-09-25 2018-12-05 IMQ-145/CTF2-A
E-CTF-2 GEWISS S.p.A. (Laboratorio Prove GW130) Via Emilia Pavese, 53 IT-29015 Castel San Giovanni Piacenza (PC) Italy [INST] EN 61386-1:2008 + A1:2017 (All clauses except 14); EN 61386-21:2004 + A11:2010 (All clauses except 14); EN IEC 61386-22:2021 + A11:2021 (All clauses except 14); EN 61386-22:2004 + A11:2010 (All clauses except 14); EN IEC 61386-22:2021 + A11:2021 (All clauses except 14); EN 61386-23:2004 + A11:2010 (All clauses except 14); EN IEC 61384-23 (All clauses except 14) 2016-04-13 2022-09-15 IMQ-284/E-CTF2 Issue No: 1
E-CTF-3 HAGER ELECTRO SAS Boulevard d'Europe, 132 FR-67210 CEDEX Obernai France [INST] EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018; EN 60669-2-2:2006; EN 60669-2-4:2005 [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses and for EMC only Immunity testing); EN IEC 60947-1:2021 (All clauses and for EMC only Immunity testing); EN 60947-2:2006 + A1:2009 + A2:2013 (All clauses and for EMC only Immunity testing); EN 60947-2:2017 + A1:2020 (All clauses and for EMC only Immunity testing); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses and for EMC only Immunity testing); EN IEC 60947-3:2021 (All clauses and for EMC only Immunity testing); EN 60947-4-1:2010 + A1:2012; EN IEC 60947-4-1:2019; EN 60947-5-1:2004 + A1:2009 (All clauses and for EMC only Immunity testing); EN 60947-5-1:2017 (All clauses and for EMC only Immunity testing) [PROT] EN 60898-1:2003 + A1:2004 + A11:2005 + A12:2008 + A13:2012; EN 60898-1:2019; EN 61008-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2017 (All clauses and for EMC only Immunity testing); EN 61008-2-1:1994 + A11:1998 (All clauses and for EMC only Immunity testing); EN 61009-1:2012 + A1:2014 + A2:2014 + A11:2015 + A12:2016 + A13:2021 (All clauses and for EMC only Immunity testing); EN 61009-2-1:1994 + A11:1998 (All clauses and for EMC only Immunity testing); EN 62423:2012 + A11:2021 + A12:2022 (All clauses and for EMC only Immunity testing) [CONT] EN 61095:2009 [SAFE] EN 61558-1:2005 + A1:2009 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X); EN IEC 61558-1:2019 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X); EN 61558-2-6:2009 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X); EN 61558-2-8:2010 (All clauses except the determination of Comparative Tracking Index (CTI) and Degrees of protection above IP2X) 2010-04-14 2023-12-21 IMQ-188/E-CTF3 Issue No: 2
E-CTF-1 ICEL S.r.l. (LABORATORIO E SALA PROVE ICEL) Via Carlo Jucker, 16 IT-21053 Castellanza Varese (VA) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.9, 5.13, 5.14) 2005-09-30 2023-05-15 IMQ-048/E-CTF1B Issue No: 2
E-CTF-2 IGUZZINI ILLUMINAZIONE S.p.A. (Laboratorio Normativo/Sicurezza) Via Mariano Guzzini, 37 IT-62019 Recanati Macerata (MC) Italy [LITE] EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.13.6, 4.20, 4.28, 4.34, 4.35, 9.2.10, 9.2.11, 13.3.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021; EN 60598-2-22:2014 + A1:2020; EN IEC 60598-2-22:2022; EN 60598-2-24:2013; EN 62031:2020 + A11:2021 (All clauses except 7, 21.1, Annex A, Annex D); EN 60570:2003 + A1:2018 + A2:2020; EN 62262:2002 + A1:2021 - IEC TR 62696:2011 (Accepted clause test Ehc (vertical hammer), according to IEC 60068-2-75:2014); IEC TR 62778:2014 [EMC] EN IEC 61000-3-2:2019 + A1:2021; EN 61000-3-3:2013 + A1:2019 + A2:2021; EN IEC 55015:2019 + A11:2020 (All clauses except: - No. 7 Method of insertion loss measurement - No. 9 Method of radiated electromagnetic disturbances (semi-anechoic chamber)); EN 61000-4-5:2014 + A1:2017 1992-02-07 2024-04-03 IMQ-011/E-CTF2 Issue No: 2
E-CTF-2 INCO MASSALOMBARDA S.r.l. (LABORATORIO SALA PROVE) Via Marchetti, 88 IT-48024 Massa Lombarda Ravenna (RA) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.15, 5.16) 2005-09-30 2023-12-01 IMQ-050/E-CTF2 Issue No: 2
E-CTF-2 ITW Appliance Components S.r.l. (ITW EMEA Laboratory) Via Oltrona, 23 IT-21020 Barasso (VA) Italy [INST] EN 60998-1:2004 (All clauses except 12.3); EN 60998-2-1:2004; EN 60998-2-2:2004; EN IEC 61058-1:2018 (Only for mechanical switches - Only for resistive-motor load); EN 61058-1-1:2016 (Only for mechanical switches - Only for resistive-motor load); EN 61058-2-4:2005 (Only for mechanical switches - Only for resistive-motor load) [HOUS] EN 60335-1:2012 + A11:2014 (Accepted clauses 25.15, 28, 30 (except 30.2.4), Annex N) 2018-09-20 2023-12-04 IMQ-343/E-CTF2 Issue No: 2
E-CTF-2 IVELA S.p.A. Via Bruno Buozzi, 15 IT-20060 Liscate Milano (MI) Italy [LITE] EN 60598-1:2015 (All clauses except 4.4.4, 4.4.5, 4.9.2, 4.12.5, 4.13.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 5.2.10.1, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.3.1, 10.3.1, 11.2.1, 13.3.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.4.5, 4.9.2, 4.12.5, 4.13.4, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 5.2.10.1, 8.2.7, 9.2.1, 9.2.2, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 10.3, 11.2.1, 13.3.1, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN 60570:2003 + A1:2018 + A2:2020 (All clauses except 12.3.1, 14); EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 12.1, 18, 20, 21, Annex D) 2005-09-23 2023-03-27 IMQ-047/E-CTF2 Issue No: 1
E-CTF-2 KEMET ELECTRONICS CORPORATION - KEMET ELECTRONICS ITALIA S.r.l. Via Sagittario, 1/3 IT-40037 Sasso Marconi Bologna (BO) Italy [CAP] EN 60252-1:2011 + A1:2013 (Accepted clauses 5.5, 5.7, 5.8, 5.9, 5.12, 5.13, 5.14, 5.15, 5.16); EN 60252-2:2011 + A1:2013 (All clauses except 5.1.17, 6); EN 60384-14:2013 + A1:2016 (Accepted clauses 4.1, 4.2, 4.3, 4.4, 4.11, 4.12, 4.13, 4.14, 4.15, 4.17, 4.18, 4.20, Annex H, Annex I); EN 60831-1:2014 (Accepted clauses 7, 8, 9, 10, 11, 12, 13, 14, 15, 16); EN 60831-2:2014 (Accepted clauses 17, 18, 19); EN 61048:2006 + A1:2016 (Accepted clauses 13, 14, 15, 17, 18); EN 61049:1993 (Accepted clauses 6, 8) 2005-09-30 2023-07-28 IMQ-052/E-CTF2 Issue No: 2
E-CTF-2 LOVATO ELECTRIC S.p.A. (LABORATORIO DI PROVA (LPR)) Via Don Emilio Mazza, 12 IT-24020 Gorle (BG) Italy [CONT] EN 60730-1:2016 + A1:2019 (Accepted clauses 11.3.5, 11.3.6, 11.3.7, 11.3.8, 17) [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.4); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses except 8.4); EN 60947-4-1:2018 (All clauses except 9.4); EN 60947-5-1:2016 (All clauses except 8.4) 2017-11-06 2021-09-27 IMQ-311/E-CTF2 Issue No: 0
E-CTF-2 MENEGHETTI S.p.A. Via Generale Cadore, 26 IT-21010 Cardano al Campo (VA) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 30); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 30); EN 60335 2-6:2015 + A1:2020 + A11:2020 (All clauses except 19.101, 19.102, 21.102, 22.110, 22.111, 22.135, 22.136, 30, 32.101); EN IEC 60335-2-25:2021 + A11:2021 (All clauses except 16, 18, 22.105, 22.106, 22.115, 22.116, 22.119, Annex BB); EN 60335-2-102:2016 (All clauses except 8.101) 2018-09-17 2024-02-12 IMQ-342/E-CTF2 Issue No: 3
E-CTF-2 PALAZZOLI S.p.A. (TEST LABORATORY) Via F. Palazzoli, 31 IT-25128 Brescia (BS) Italy [INST] EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 29, 30); EN IEC 60309-1:2021 (All clauses except 29, 30); EN 60309-2:1999 + A1:2007 + A2:2012 (All clauses except 29,30); EN IEC 60309-2:2021 (All clauses except 29, 30); EN 60309-4:2007 + A1:2012 (All clauses except 29, 30); EN IEC 60309-4:2021 (All clauses except 29, 30); EN 62208:2011 (All clauses except 9.5, 9.12, 9.13) [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (Accepted clauses 5, 7.1.2.2, 8.3.3.3, 8.3.3.4 (excluded impulse withstand voltage), 8.3.3.6, 8.3.3.7); EN IEC 60947-1:2021 (Accepted clauses 8.1.2.2, 8.1.12 + Annex C, 9.3.3.3, 9.3.3.4 (excluded impulse withstand voltage), 9.3.3.6, 9.3.3.7); EN 60947-3:2009 + A1:2012 + A2:2015 (Accepted clauses 5, 7.1.2.2 Test Sequence II (8.3.4.1, 8.3.4.2, 8.3.4.3, 8.3.4.4), 8.5.1, 8.5.2); EN IEC 60947-3:2021 (Accepted clauses 8.1.2.2, Test Sequence II (9.3.5.2, 9.3.5.3, 9.3.5.4, 9.3.5.5), 9.5.2, 9.5.3) 2006-03-16 2024-02-16 IMQ-062/E-CTF2 Issue No: 2
E-CTF-2 PERFORMANCE IN LIGHTING S.p.A. Viale del Lavoro, 9/11 IT-37030 Colognola ai Colli Verona (VR) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.3, 10.3.1, 11.2.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.13.6, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 9.2.3, 9.2.9, 9.2.10, 9.2.11, 10.3.1, 11.2.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2 g), 12.1, 17, 18, 20, 21, Annex D) 2005-04-14 2023-11-09 IMQ-021/E-CTF2 Issue No: 2
E-CTF-2 PIZZATO ELETTRICA S.r.l. (Laboratorio Prove P6) Corso della Ceramica, 56/B IT-36063 Marostica Vicenza (VI) Italy [POW] EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.1.2.2, 8.4.1.2.3, 8.4.1.2.6, 8.4.1.2.7, 8.4.2, Annex K - For Annex C (Degrees of protection of enclosed equipment): Applicable clauses 14.2.4, 14.2.5, 14.2.6, 14.2.7, 14.2.8 of EN 60529:1991 + A1:2000 + A2:2013); EN IEC 60947-1:2020 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.1.2.2, 8.4.1.2.3, 8.4.1.2.6, 8.4.1.2.7, 8.4.2 - For Annex C (Degrees of protection of enclosed equipment): Accepted clauses 14.2.4, 14.2.5, 14.2.6, 14.2.7, 14.2.8 of IEC 60529:1989 + A1:1999 + A2:2013 / EN 60529:1991 + A1:2000 + A2:2013; EN 60947-5-1:2004 + A1:2009 (All clauses except 8.3.4); EN 60947-5-1:2017 (All clauses except 8.2.1.1.1, 8.3.4, 8.4.2.1, 8.4.2.2, 8.4.2.5, 8.4.2.6, 8.4.3); EN 60947-5-5:1997 + A1:2005 + A11:2013 + A2:2017 (All clauses except Annex A) 2020-09-02 2024-02-23 IMQ-375/E-CTF2 Issue No: 2
E-CTF-2 RELCO S.r.l. Via delle Azalee, 6/A IT - 20090 Buccinasco (MI) Italy [LITE] EN 60598-1:2015 + A1:2018 (Accepted clauses 3, 7, 10.2, 11, 12); EN IEC 60598-1:2021 + A11:2022 (Accepted clauses 3, 7, 10.2, 11, 12); EN 60598-2-2:2012 (Accepted clauses 2.6, 2.8, 2.9, 2.13, 2.15); EN 60598-2-3:2003 + A1:2011 (Accepted clauses 3.5, 3.7, 3.8, 3.12, 3.14); EN 60598-2-5:2015 (Accepted clauses 5.5, 5.7, 5.8, 5.12, 5.14); EN 61347-1:2015 + A1:2021 (Accepted clauses 7, 9, 12, 13, 15, 16, 20); EN 61347-2-7:2012 + A1:2019 (All clauses except 8, 9, 11, 14, 15, 16, 17, 18, 19, 20.1, 31, 32, 33, 34.2, 34.5, 35); EN 61347-2-13:2014 + A1:2017 (Accepted clauses 7, 10, 12, 13, 15, 17, 21, Annex J (except J.7, J.8)) 2022-03-25 2023-11-09 IMQ-416/E-CTF2 Issue No: 1
E-CTF-2 SCAME PARRE S.p.A. Via Campignano, 9 IT-24020 Parre Bergamo (BG) Italy [INST] EN 50085-1:2005 + A1:2013; EN 50085-2-1:2006 + A1:2011; EN 61386-1:2008 + A1:2019; EN 61386-21:2004 + A11:2010; EN IEC 61386-21:2021 + A11:2021; EN 61242:1997 + A1:2008 + A2:2016 + A13:2017; EN 60309-1:1999 + A1:2007 + A2:2012 (All clauses except 20 and 21 (for equipment with rated operating voltage > 400V and rated current > 32A)); EN IEC 60309-1:2022 (All clauses except 20 and 21 (for equipment with rated operating voltage > 400 V and rated current > 32 A)); EN 60309-2:1999 + A1:2007 + A2:2012; EN IEC 60309-2:2022; EN 60309-4:2007 + A1:2012; EN IEC 60309-4:2022; EN 61316:1999; EN IEC 61316:2021; EN 50250:2002 + A1:2015; EN 60669-1:1999 + A1:2002 + A2:2008; EN 60669-1:2018 (All clauses except 19.3); EN 60998-1:2004; EN 60998-2-1:2004; EN 60670-1:2005 + A1:2013; EN IEC 60670-1:2021 + A1:2021; EN 60670-22:2006; EN 60670-24:2013; EN 62208:2011 (All clauses except 9.13); EN IEC 62208:2023 (All clauses except 9.14) [ELVH] EN 62196-1:2014 (All clauses except 22, 23 and 31); EN IEC 62196-1:2022 (All clauses except 22, 23, 31); EN 62196-2:2017; EN IEC 62196-2:2022; EN 62196-3:2014 (All clauses except 26.4); EN IEC 62196-3:2022 (All clauses except 26.4) [POW] EN 61439-1:2011 (All clauses except 10.2.2); EN 61439-1:2021 (All clauses except 10.2.2); EN 61439-4:2013 (All clauses except 10.2.6.3, 10.2.2.101); EN 60947-1:2007 + A1:2011 + A2:2014 (All clauses except 8.3.3); EN IEC 60947-1:2021 (All clauses except 9.3); EN 60947-3:2009 + A1:2012 + A2:2015 (All clauses except 8.3.3, 8.3.5, 8.3.6); EN IEC 60947-3:2021 (All clauses except 9.3.4, 9.3.6, 9.3.7, 9.3.8, 9.3.9) 2005-11-11 2024-03-21 IMQ-069/E-CTF2 Issue No: 3
E-CTF-2 SCHNEIDER ELECTRIC INDUSTRIE ITALIA S.p.A. Via Govoni, 17 IT-40066 Pieve di Cento Bologna (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.12.5, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 9.2.1, 9.2.2, 9.2.7, 9.2.8, 9.2.9, 10.3.1, 12.5.1e), Annex C Fig. C3); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.12.5, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 9.2.1, 9.2.2, 9.2.5, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 10.3, 12.5 1e), Annex C Fig. C3); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-22:2014 + A1:2020; EN IEC 60598-2-22:2022; EN 61347-1:2015 + A1:2021 (All clauses except 14.6, 17, 18.2, 19); EN 61347-2-7:2012 + A1:2019 + A2:2022 (All clauses except 4.4.5 of IEC 62034 (prescribed in Annex K)); EN 62262:2002 - IEC TR 62696:2011 2006-02-22 2023-07-28 IMQ-090/E-CTF2 Issue No: 1
E-CTF-2 SIMES S.p.A. Via G. Pastore, 2/4 IT-25040 Nigoline di Corte Franca Brescia (BS) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.4.4, 4.13.6, 4.20, 4.24 / Annex P, 4.26, 4.28, 5.2.10.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.4.4, 4.13.6, 4.20, 4.24.1 / Annex P, 4.26, 4.28, 4.34, 4.35, 4.36, 5.2.10.1, 9.2.10, 9.2.11, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021; EN 60598-2-18:1994 + A1:2012; EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 13.1, 18, 20, 21.1/21.3, Annex A, Annex D); IEC/TR 62778:2014 2010-01-21 2023-05-02 IMQ-236/E-CTF2 Issue No: 1
E-CTF-2 TARGETTI SANKEY S.p.A. (LABORATORIO PROVE TARGETTI) Via Pratese, 164 IT-50145 Firenze Firenze (FI) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.9.2, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.3.1, 11.2.1, 12.7.2, 13.3.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.9.2, 4.11.6, 4.13.6, 4.14.3, 4.18.2 / Annex F, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.9, 9.2.10, 9.2.11, 9.3.1, 11.2.1, 12.7.2, 13.3.1, 13.3.2, 13.4.1); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021; EN IEC 62031:2020 + A11:2021 (All clauses except 4.8, 6.2 g), 7, 10, 16, 17, 18, 20, 21, Annex A, Annex D) 1994-01-26 2023-06-22 IMQ-014/E-CTF2 Issue No: 2
E-CTF-1 TECNOINOX S.r.l. (Laboratorio TECNOINOX) Via Torricelli, 1 IT - 33080 Porcia (PN) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15, 19.11.4 (EMP), 22, 25, 26, 27, 28, 30, Annex E, Annex N, Annex T); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 8, 14, 15, 19.11.4 (EMP), 22, 25, 26, 27, 28, 30, Annex E, Annex N); EN 60335-2-48:2003 + A1:2008 + A11:2012 (All clauses ) 2018-10-05 2018-10-05 IMQ-344/CTF1
E-CTF-2 TEKA INDUSTRIAL S.A. (TEKA Laboratory Gas Competence Center) Via Alcide De Gasperi, 20 IT-36060 Pianezze San Lorenzo Vicenza (VI) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 21.2, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 29, 30); EN 60335-1:2012 + A11:2014 + A13:2017 (All clauses except 8, 14, 15.1, 15.3, 19.11.4, 21.2, 22.11, 22.12, 22.16, 25.14, 25.15, 26, 28, 29, 30); EN 60335-2-6:2015 (All clauses except 8, 19.101, 19.102, 21.102, 22.110, 22.111, 22.135, 22.136, 30, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2022-06-13 2022-06-13 IMQ-418/E-CTF2 Issue No: 0
E-CTF-2 VIABIZZUNO S.r.l. (Laboratorio Prove Viabizzuno) Via L. Romagnoli, 10 IT-40010 Bentivoglio (BO) Italy [LITE] EN 60598-1:2015 + A1:2018 (Accepted clauses: 3.4, 4.11.6, 4.12.1, 4.12.5, 4.13.1, 4.13.3, 4.14, 4.21.4, 4.26, 5.2.10.1, 5.3, 5.4, 7.2.3, 8.2.5, 9.2.0, 10.2.1, 10.2.2, 10.2.3, 11.2.1, 12.3.1, 12.4.1, 12.5.1 e), Annex C Fig. C3, 14, 4.6.3, 4.12); EN IEC 60598-1:2021 + A11:2022 (Accepted clauses: 3.4, 4.11.6, 4.12.1, 4.12.5, 4.13.1, 4.13.3, 4.14, 4.21.4, 4.26, 4.33, 4.36, 5.2.10.1, 5.3, 5.4, 7.2.3, 8.2.5, 9.2.0, 10.2.1, 10.2.2, 10.2.3, 11.2.1, 12.3.1, 12.4.1, 12.5.1 e), Annex C Fig. C3, 14, 4.6.3, 4.12); EN 60598-2-1:1989; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-4:2018; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (Accepted clauses: 13.5, 13.6.4, 13.6.5, 13.7, 13.8, 13.9, 13.10, 13.11, 13.12, 13.14, 13.15); EN IEC 62031:2020 + A11:2021 (Accepted clauses: 6.6, 7, 8, 9, 11, 12, 15, 16); EN 61347-1:2015 + A1:2021 (Accepted clauses: 7.2, 10, 12, 14 (excl. 14.7), 16, L.6, L.7); EN 61347-2-11:2001 + A1:2019 (Accepted clauses: 7, 8, 12, 14, 16 (only d.c. supplied miscellaneous electronic circuits used with luminaires up to 48 Vd.c.); EN 61347-2-13:2014 + A1:2017 (Accepted clauses: 7, 8, 12, 14, 15, 17 (only d.c. supplied controlgear up to 48 Vd.c.) 2020-09-25 2023-11-09 IMQ-379/E-CTF2 Issue No: 1
E-CTF-2 VIMAR S.p.A. [Prod. Cat.: INST - PROT] Via IV Novembre, 32 IT-36063 Marostica Vicenza (VI) Italy [INST] EN 61242:1997 + A1:2008 + A2:2016 + A13:2017 (All clauses except 25.2); EN 60669-1:1999 + A1:2002 + A2:2008 (All clauses except 24.2); EN 60669-1:2018 (All clauses except 24.2); EN 60669-2-1:2004 + A1:2009 + A12:2010 (All clauses except 24.2, 26); EN IEC 60669-2-1:2022 + A11:2022 (All clauses except 24.2, 26, 103); EN 60669-2-5:2016 (All clauses except 24.2, 26); EN 60670-1:2005 + A1:2013 (All clauses except 19); EN IEC 60670-1:2021 + A11:2021 (All clauses except 19); EN 60670-22:2006 (All clauses except 19); EN 60670-24:2013 (All clauses except 19) 2005-12-05 2024-02-16 IMQ-084/E-CTF2 Issue No: 1
E-CTF-2 VORTICE S.p.A. (Laboratorio prove R&D) Strada Cerca, 2 IT-20067 Tribiano Milano (MI) Italy [HOUS] EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.48); EN 60335-2-30:2009 + A11:2012 + A1:2020 + A12:2020; EN 60335-2-80:2003 + A1:2004 + A2:2009 2007-06-28 2022-04-22 IMQ-114/E-CTF2 Issue No: 1
E-CTF-2 ZOBELE HOLDING S.p.A. (Electrical Testing Laboratory) Via Fersina, 4 IT-38123 Trento Trento (TN) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 + A14:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 25.14, 27.5); EN 60335-2-101:2002 + A1:2008 + A2:2014 2006-10-17 2022-07-15 IMQ-100/E-CTF2 Issue No: 0
E-CTF-3 CANDY HOOVER GROUP S.r.l. (Cooking & Built-in Lab) Via Comolli, 16 IT-20861 Brugherio Monza-Brianza (MB) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, from 19.11.4.1 to 19.11.4.7); EN 60335-2-6:2015 + A1:2020 + A11:2020 (All clauses except 22.110, 22.111, 22.135, 22.136, 22.137, 32.101); EN 60335-2-102:2016 (All clauses except 8.101) 2021-12-01 2021-12-01 IMQ-403/E-CTF3 Issue No: 0
E-CTF-2 DE’ LONGHI APPLIANCES S.r.l. (Laboratorio MCM (Macchine Caffè Manuali)) Via Lodovico Seitz, 47 IT-31100 Treviso Treviso (TV) Italy [HOUS] EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021 (All clauses except 14, 15.1, 19.11.4 (EMP), 22.32, 22.48, Annex N, Annex R, Annex T); EN 60335-2-14:2006 + A1:2008 + A11:2012 + A12:2016; EN 60335-2-15:2016 + A11:2018 + A12:2021 + A1:2021 + A2:2021 2022-02-10 2023-09-26 IMQ-408/E-CTF2 Issue No: 1
E-CTF-2 ARTEMIDE S.p.A. (ARTEMIDE LABORATORY) Via Bergamo, 17 IT - 20006 Pregnana Milanese (MI) Italy [LITE] EN 60598-1:2015 + A1:2018 (All clauses except 4.13.6, 4.20, 4.24 / Annex P, 4.28, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 12.5.1e Annex C Fig. C3, 13.3.1, 13.4.1); EN IEC 60598-1:2021 + A11:2022 (All clauses except 4.13.6, 4.20, 4.24 / Annex P, 4.28, 4.34, 4.35, 9.2.1, 9.2.2, 9.2.3, 9.2.4, 9.2.5, 9.2.6, 9.2.7, 9.2.8, 9.2.9, 9.2.10, 9.2.11, 12.5.1e Annex C Fig. C3, 13.3.1, 13.4.1); EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN 60598-2-3:2003 + A1:2011; EN 60598-2-4:2018; EN 60598-2-5:2015; EN 60598-2-13:2006 + A1:2012 + A2:2016 + A11:2021 (All clauses except 13.6.1, 13.6.2.1, 13.6.2.2); EN IEC 60598-2-22:2022 (All clauses except 22.13, 22.17.1 Annex C, 22.19); EN IEC 60598-2-23:2021; EN IEC 62031:2020 + A11:2021 (All clauses except 12.1, 18, 21); EN 61347-1:2015 + A1:2021 (Accepted clause 14 except 14.7); EN 61347-2-11:2001 + A1:2019 (Accepted clause 14); EN 61347-2-13:2014 + A1:2017 (Accepted clause 14) 2023-05-10 2023-05-10 IMQ-428/E-CTF2 Issue No: 0
Scheme Given name Family name Location Certification decision Signatory Scope limitation Terminated
ENEC+ Fulvio Giorgi Milano 2014-01-01
ENEC, CCA, CCA/NTR, CCA/EMC, HAR Giorgio Belussi Milano 2017-01-01 2017-01-01
ENEC+ Giorgio Belussi Milano 2014-01-01 2014-01-01
ENEC, CCA, CCA/NTR, CCA/EMC, HAR Mauro Casari Milano 2008-01-01 2008-01-01
ENEC+ Mauro Casari Milano 2014-01-01 2014-01-01
HAR Marco Piazza Milano 2005-01-01 2005-01-01 CABL
ENEC, CCA Marco Piazza Milano 2005-01-01 2005-01-01 LITE, SAFE
CCA/NTR Marco Piazza Milano 2005-01-01 2023-03-01 CABLE, LITE, SAFE
ENEC, CCA Fabrizio Stucchi Milano 2013-01-01 2013-01-01 LITE, SAFE 2016-12-31
CCA/NTR Fabrizio Stucchi Milano 2013-01-01 LITE, SAFE 2016-12-31
ENEC, CCA Massimiliano Rancati Milano 2016-01-01 2016-01-01 LITE, SAFE 2019-12-31
CCA/NTR Massimiliano Rancati Milano 2016-01-01 LITE, SAFE 2019-12-31
ENEC, CCA Augusto Ciciotti Milano 2005-01-01 2005-01-01 INST, PROT, POW, MISC 2017-12-31
CCA/NTR Augusto Ciciotti Milano 2005-01-01 INST, PROT, POW, MISC 2017-12-31
ENEC, CCA Fabio Taormina Milano 2017-01-01 2017-01-01 CONT, ELVH, INDA, INST, MISC, POW, PROT
CCA/NTR Fabio Taormina Milano 2017-01-01 2013-03-01 CONT, ELVH, INDA, INST, MISC, POW, PROT
ENEC, CCA Armando Benvenuti Milano 2008-01-01 2008-01-01 HOUS, TOOL
CCA/NTR Armando Benvenuti Milano 2008-01-01 2023-03-01 HOUS, TOOL
ENEC, CCA Stefano De Mas Milano 2014-01-01 2014-01-01 CAP, HOUS, MED, MEAS 2023-08-31
CCA/NTR Stefano De Mas Milano 2014-01-01 CAP, HOUS, MED, MEAS 2023-08-31
ENEC, CCA, CCA/NTR, CCA/EMC, HAR Fulvio Giorgi Milano 2011-01-01
ENEC, CCA Mauro Agnolet Milano 2019-01-01 2019-01-01 CAP, ITAV, OFF, TRON
CCA/NTR Mauro Agnolet Milano 2019-01-01 2023-03-01 CAP, ITAV, OFF, TRON
ENEC, CCA, CCA/NTR, CCA/EMC Flavio Cimardi Milano 2020-01-01 2023-03-01 CONT, EMC, INST, MEAS, MED
Given name Family name Location Registered date Terminated date
Giorgio Belussi Italy 2021-04-09
Luca Bergamo Italy 2021-04-09
Paolo Brambilla Italy 2021-04-09
Filippo Brivio Italy 2021-04-09
Bruno Brusaferri Brazil 2021-04-09
Andrea Capitanelli Italy 2021-04-09
Giuseppe Cassano Italy 2021-04-09
Fulvio Colombo Italy 2021-04-09
Massimo Di Dionisio Italy 2021-04-09
Diego Ferrari Italy 2021-04-09 2022-09-05
Filippo Fiorentini Italy 2021-04-09
Antonio Forcina Italy 2021-04-09
Stefano Grilli Italy 2021-04-09
Paolo Magnani Italy 2021-04-09
Mario Marchelli Italy 2021-04-09
Roberto Mollo Italy 2021-04-09
Pasquale Pastocchi Italy 2021-04-09
Paolo Raffa Italy 2021-04-09
Livio Righetto Italy 2021-04-09
Giovanni Rodella Italy 2021-04-09 2022-08-24
Davide Sanvito Italy 2021-04-09
Giuseppe Scuderini Italy 2021-04-09 2023-05-01
Marco Tagliaferri Italy 2021-04-09
Claudio Veronese Italy 2021-04-09
Natalino Verzotto Italy 2021-04-09
Raffaele Villa Italy 2021-04-09
Berk Biricik Turkey 2021-04-09
Jorge López Spain 2021-04-09 2023-11-30
Ming (Simeon) Chen China 2021-04-09
Yafeng (Ivan) Cheng China 2021-04-09
TiaoHui (William) Liu China 2021-04-09
Gabriele Panzeri China 2021-04-09
HongYun (Terry) Qiu China 2021-04-09
Aike (Echo) Yang China 2021-04-09 2022-01-01
Mingjun (Stephen) Zhou China 2021-04-09
Anna Wronska Poland 2023-10-17
Riccardo Barbaro China 2021-04-09
David Latorre Diaz Spain 2024-02-09